Single-leaf sliding gates in EI 60 and EI 120 class
Sliding, single-leaf fire doors in EI class are a proven solution that provides protection against fire as well as thermal radiation.
They can be equipped with threshold-free emergency exit doors.
The gate’s construction with the applied equipment ensures its automatic and safe gravitational closure after the release of the electromagnet.
The doors can be equipped with control systems with a set of batteries, allowing connection to the Fire Alarm System (FAS).
Simplicity of operation
Reliable construction
Integration with FAS
Gravitational closure
Product features
- closing speed regulator and/or shock absorber
- gravitational closing
- variant with emergency doors
- holding in open position with electromagnet
- possible integration with FAS
Specification
| PRODUCT TYPE | sliding gates, single-leaf |
| DIRECTION OF MOVEMENT | horizontal |
| PURPOSE | closure of openings in vertical building partitions |
| RESISTANCE CLASS | EI 60, EI 120 |
| APPROVAL DOCUMENTS | CE 0370-CPR-5958 issued by Applus [no. 0370] |
| HARMONISED STANDARDS | EN 16034, EN 13241 |
| GATE’S WEIGHT | 21 – 23 kg/m2 |
| PANEL COLOR | RAL 7035, 9002, 9010 |
| PANEL FITTINGS, STEEL PARTS | galvanized |
| DIMENSIONS | CE 7960 mm x 6395 mm (W x H) |
| MINIMUM INSTALLATION DIMENSIONS | lintel: 280mm doorstop: 250mm opening side: opening width + 180mm |
Additional options
- smoke detectors, manual fire alarm call points, optical and audible signal indicators
- painting of steel elements in any color from the RAL palette
- corrosion protection / painting in anti-corrosion classes from C3 to C5
- made of stainless steel
- electric drive assisting gate opening
- fuse instead of electromagnet
Documents
Our materials are at your disposal. Download and explore the details.
- declaration of performance single leaf EI 60 & EI 120
- Building conditions single leaf EI 60 closing to the left, standard counterweight
- Building conditions single leaf EI 60 closing to the left, rear counterweight
- Building conditions single leaf EI 60 closing to the right, standard counterweight
- Building conditions single leaf EI 60 closing to the right, rear counterweight
- Building conditions single leaf EI 120 closing to the left, standard counterweight
- Building conditions single leaf EI 120 closing to the left, rear counterweight
- Building conditions single leaf EI 120 closing to the right, standard counterweight
- Building conditions single leaf EI 120 closing to the right, rear counterweight
- Building conditions single leaf with drive
- assembly manual single leaf EI 60 & EI 120
- Product card - Sliding gate single-leaf EI 60 & EI 120